Tecan Infinite F200 PRO Fluorescence Plate Reader with Control PC

$4,995.00

Tecan i-control Software Installed | USB Communication Verified | Basic Functional Testing Performed

The Tecan Infinite F200 PRO is a fluorescence microplate reader designed for laboratory applications requiring fluorescence intensity and fluorescence polarization measurements.

This pre-owned instrument is offered with an HP Z2 control computer running Tecan i-control software, installed and configured to communicate with the reader.

The system underwent an in-house technical assessment by LabCycle Partners on October 19 and 26, 2026. The assessment confirmed instrument recognition, two-way USB communication, software connectivity, initialization, and observed filter-slide movement.

A detailed technical assessment report is available upon request.

Instrument Specifications

  • Manufacturer: Tecan Austria GmbH

  • Brand: Tecan

  • Model: Infinite F200 PRO (Infinite 200 PRO series)

  • Reference Number: 30050303

  • Serial Number: 1207007475

  • Manufacturing Date: August 8, 2012

  • Power Requirements: 100–120 / 220–240 VAC, 50/60 Hz

  • Power Consumption: 150 VA

  • Country of Manufacture: Austria

Installed Instrument Options

The manufacturer's identification label confirms the following installed options:

  • 30050156 — Filter FI Top

  • 30015905 — Filter Polarisation

  • 30015896 — PMT Standard

The connected Tecan i-control software displays the following measurement modes:

  • Fluorescence Intensity

  • Fluorescence Polarization

Control Computer & Software

The instrument includes an HP Z2 control computer configured for operation with the reader.

  • Windows-based HP Z2 workstation

  • Tecan i-control software, version 2.0.10

  • Software installed and configured for this instrument

  • USB communication established and verified

  • Instrument model and serial number recognized by the software

The software successfully identifies the connected reader as Infinite 200 PRO, serial number 1207007475.

Technical Assessment & Functional Testing

Assessment Dates: October 19 and 26, 2026

Technician: Dave Gronbach — LabCycle Partners

The following checks were performed:

1. Power-On and Instrument Recognition — PASSED

The instrument powers on and identifies itself through its USB interface. The reported serial number matches the physical identification label.

2. USB Communication — PASSED

Two-way USB communication was verified. The instrument successfully received commands and returned valid responses.

3. Instrument Identity Verification — PASSED

Repeated identity queries returned the correct instrument serial number.

4. Instrument Initialization — PASSED

The instrument responded to an initialization command. Internal mechanical movement was heard during the process and described by the technician as smooth, without grinding or repeated clicking.

5. Tecan i-control Software Connection — PASSED

The supplied computer successfully connected to the reader through Tecan i-control. The software displayed the correct instrument model and serial number.

6. Filter Slide Movement — OBSERVED

The filter slide was moved outward using the i-control software. It returned to its internal position after the instrument was powered off and restarted.

Testing Limitations

The manufacturer's full performance verification procedures have not been completed.

The following have not been independently verified:

  • Fluorescence intensity sensitivity, uniformity, and precision

  • Fluorescence polarization precision

  • Analytical performance using reference samples and microplates

  • Temperature control and shaking performance

Absorbance and luminescence measurement modes were not available in the connected software's measurement list and are not represented as verified capabilities of this configuration.

The instrument has been tested for communication, software connectivity, initialization, and observed mechanical movement. Full analytical performance and calibration have not been certified.

Download Technical Assessment Report (PDF)

Included Items

  • Tecan Infinite F200 PRO microplate reader

  • HP Z2 control computer with Tecan i-control 2.0.10 installed

  • USB communication cable

  • AC power cord

Please refer to the photographs for the equipment's physical condition and configuration.

Condition

Pre-owned laboratory equipment in good cosmetic condition, with normal signs of previous use.

The instrument powers on, communicates successfully with the supplied computer, and responds to initialization commands. Filter-slide movement was also observed during testing.

Full analytical performance testing with reference samples has not been completed.

Shipping & Pickup

Freight shipping is available throughout the United States. Shipping costs are quoted separately based on destination, delivery requirements, and final shipment dimensions.

Local pickup is available in San Diego, California.

Please complete the Freight & Local Pickup Request Form before purchasing to receive an accurate freight quote.

Tecan i-control Software Installed | USB Communication Verified | Basic Functional Testing Performed

The Tecan Infinite F200 PRO is a fluorescence microplate reader designed for laboratory applications requiring fluorescence intensity and fluorescence polarization measurements.

This pre-owned instrument is offered with an HP Z2 control computer running Tecan i-control software, installed and configured to communicate with the reader.

The system underwent an in-house technical assessment by LabCycle Partners on October 19 and 26, 2026. The assessment confirmed instrument recognition, two-way USB communication, software connectivity, initialization, and observed filter-slide movement.

A detailed technical assessment report is available upon request.

Instrument Specifications

  • Manufacturer: Tecan Austria GmbH

  • Brand: Tecan

  • Model: Infinite F200 PRO (Infinite 200 PRO series)

  • Reference Number: 30050303

  • Serial Number: 1207007475

  • Manufacturing Date: August 8, 2012

  • Power Requirements: 100–120 / 220–240 VAC, 50/60 Hz

  • Power Consumption: 150 VA

  • Country of Manufacture: Austria

Installed Instrument Options

The manufacturer's identification label confirms the following installed options:

  • 30050156 — Filter FI Top

  • 30015905 — Filter Polarisation

  • 30015896 — PMT Standard

The connected Tecan i-control software displays the following measurement modes:

  • Fluorescence Intensity

  • Fluorescence Polarization

Control Computer & Software

The instrument includes an HP Z2 control computer configured for operation with the reader.

  • Windows-based HP Z2 workstation

  • Tecan i-control software, version 2.0.10

  • Software installed and configured for this instrument

  • USB communication established and verified

  • Instrument model and serial number recognized by the software

The software successfully identifies the connected reader as Infinite 200 PRO, serial number 1207007475.

Technical Assessment & Functional Testing

Assessment Dates: October 19 and 26, 2026

Technician: Dave Gronbach — LabCycle Partners

The following checks were performed:

1. Power-On and Instrument Recognition — PASSED

The instrument powers on and identifies itself through its USB interface. The reported serial number matches the physical identification label.

2. USB Communication — PASSED

Two-way USB communication was verified. The instrument successfully received commands and returned valid responses.

3. Instrument Identity Verification — PASSED

Repeated identity queries returned the correct instrument serial number.

4. Instrument Initialization — PASSED

The instrument responded to an initialization command. Internal mechanical movement was heard during the process and described by the technician as smooth, without grinding or repeated clicking.

5. Tecan i-control Software Connection — PASSED

The supplied computer successfully connected to the reader through Tecan i-control. The software displayed the correct instrument model and serial number.

6. Filter Slide Movement — OBSERVED

The filter slide was moved outward using the i-control software. It returned to its internal position after the instrument was powered off and restarted.

Testing Limitations

The manufacturer's full performance verification procedures have not been completed.

The following have not been independently verified:

  • Fluorescence intensity sensitivity, uniformity, and precision

  • Fluorescence polarization precision

  • Analytical performance using reference samples and microplates

  • Temperature control and shaking performance

Absorbance and luminescence measurement modes were not available in the connected software's measurement list and are not represented as verified capabilities of this configuration.

The instrument has been tested for communication, software connectivity, initialization, and observed mechanical movement. Full analytical performance and calibration have not been certified.

Download Technical Assessment Report (PDF)

Included Items

  • Tecan Infinite F200 PRO microplate reader

  • HP Z2 control computer with Tecan i-control 2.0.10 installed

  • USB communication cable

  • AC power cord

Please refer to the photographs for the equipment's physical condition and configuration.

Condition

Pre-owned laboratory equipment in good cosmetic condition, with normal signs of previous use.

The instrument powers on, communicates successfully with the supplied computer, and responds to initialization commands. Filter-slide movement was also observed during testing.

Full analytical performance testing with reference samples has not been completed.

Shipping & Pickup

Freight shipping is available throughout the United States. Shipping costs are quoted separately based on destination, delivery requirements, and final shipment dimensions.

Local pickup is available in San Diego, California.

Please complete the Freight & Local Pickup Request Form before purchasing to receive an accurate freight quote.