Image 1 of 11
FisherBrand Explosion Proof Undercounter Freezer
This unit comes from a laboratory that was downsizing operations. This explosion proof undercounter freezer was tested for temperature and thoroughly cleaned. This unit is in Like New condition. From the manufacturer:
MODEL 05EFEEFSA
Features:
• 5.0 cubic ft. under-counter freezer
• Adjustable Mechanical thermostat
• UL Listed
• Magnetic gasket
• Hermetically-sealed compressor
• Manual defrost
• White color
• 3 Wired shelves and 3 door shelves
Model 05EFEEFSA
Freezer Chamber Dimensions H x W x D inches (cm) 29.5" x 18.63" x 19" (74.9 x 47.32 x 48.2 cm)
Total Vol. Cu. Ft. 5.0
Exterior Dimensions H x W x D inches (cm) 33.13" x 21.38" x 30.25" (84.15 x 54.3 x 64.5 cm)
Electrical Characteristics Volts/Hz, Amps 115/60, 1.1
Freezer Temp.Range °C (°F) -12 to -24 (10.4 to -11.2)
Net Wt. Lbs. (kg) 90 (41)
Overview Conventional freezers are not suitable for storing flammable materials. Such units have components in their electrical and refrigeration systems that can trigger explosions of flammable air-vapor mixtures inside the unit and/or in the immediate surrounding area. The Authority Having Jurisdiction (AHJ) determines if work areas are designated as a hazardous location with respect to the presence of flammable gases or vapors. Such locations are defined in (National Fire Protection Association) NFPA 70 Articles 500-501 and OSHA 29 CFR1910.307. Some of these classified areas are expected to experience concentrations of flammable gases and/or vapors at or above their lower flammability limits for extended periods of time. The construction of our explosion-proof units has been evaluated by Underwriters Laboratories (UL) and are suitable for use in classified areas requiring Class I, Groups C and D* protected equipment. The electrical components such as thermostats, wiring, splices, relays and compressor motors on explosion proof units are safely housed within explosionproof enclosures and conduit. Compressor surface temperatures have been evaluated and determined to remain below the flash point of materials found in Class I, Groups C and D. All models have heavy-gauge, rigid, steel construction with a durable enamel finish. Interiors have epoxy enamel or ABS plastic construction. Each unit is insulated throughout for energy-efficient operation. These units are ideal for storing cyclopropane, ethyl ether, ethylene, acetone, alcohol, benzene, butane, gasoline, hexane, lacquer solvent vapors, naphtha, natural gas or propane along with many other potentially hazardous materials.
WARNING: For FMS and EXP units where flammable materials are stored in the cooling chamber, the cooling chamber is considered a Class I Div1 or Class I Zone 1 hazardous location. Any monitoring devices placed in the cooling chamber must have an intrinsically safe rating from an appropriate certification body, such as UL, CSA, FM etc. (this includes battery or solar powered devices). Thermocouples for building monitoring systems must be wired through an electrical barrier designed to provide isolation against voltage and current spikes, which could cause a spark resulting in fire or explosion. It is the end user's responsibility to meet these requirements. The Fisher Scientific channel cannot assist with the selection of devices, recommend, approve or design any device or monitoring circuit.
If you are in the Southern California area and would like to save on shipping costs, please contact us before purchase to coordinate local pickup!
Shipping & Pickup Disclaimer
This item is listed for local pickup in the San Diego area. If you require shipping, please note that freight is billed separately and calculated on a case-by-case basis through our freight partners. We will provide you with a custom shipping quote as quickly as possible after purchase.
For the most accurate estimate, please contact us in advance with your delivery address and any special requirements (e.g., lift gate service, residential delivery). We work to make freight logistics smooth and cost-effective for you.
This unit comes from a laboratory that was downsizing operations. This explosion proof undercounter freezer was tested for temperature and thoroughly cleaned. This unit is in Like New condition. From the manufacturer:
MODEL 05EFEEFSA
Features:
• 5.0 cubic ft. under-counter freezer
• Adjustable Mechanical thermostat
• UL Listed
• Magnetic gasket
• Hermetically-sealed compressor
• Manual defrost
• White color
• 3 Wired shelves and 3 door shelves
Model 05EFEEFSA
Freezer Chamber Dimensions H x W x D inches (cm) 29.5" x 18.63" x 19" (74.9 x 47.32 x 48.2 cm)
Total Vol. Cu. Ft. 5.0
Exterior Dimensions H x W x D inches (cm) 33.13" x 21.38" x 30.25" (84.15 x 54.3 x 64.5 cm)
Electrical Characteristics Volts/Hz, Amps 115/60, 1.1
Freezer Temp.Range °C (°F) -12 to -24 (10.4 to -11.2)
Net Wt. Lbs. (kg) 90 (41)
Overview Conventional freezers are not suitable for storing flammable materials. Such units have components in their electrical and refrigeration systems that can trigger explosions of flammable air-vapor mixtures inside the unit and/or in the immediate surrounding area. The Authority Having Jurisdiction (AHJ) determines if work areas are designated as a hazardous location with respect to the presence of flammable gases or vapors. Such locations are defined in (National Fire Protection Association) NFPA 70 Articles 500-501 and OSHA 29 CFR1910.307. Some of these classified areas are expected to experience concentrations of flammable gases and/or vapors at or above their lower flammability limits for extended periods of time. The construction of our explosion-proof units has been evaluated by Underwriters Laboratories (UL) and are suitable for use in classified areas requiring Class I, Groups C and D* protected equipment. The electrical components such as thermostats, wiring, splices, relays and compressor motors on explosion proof units are safely housed within explosionproof enclosures and conduit. Compressor surface temperatures have been evaluated and determined to remain below the flash point of materials found in Class I, Groups C and D. All models have heavy-gauge, rigid, steel construction with a durable enamel finish. Interiors have epoxy enamel or ABS plastic construction. Each unit is insulated throughout for energy-efficient operation. These units are ideal for storing cyclopropane, ethyl ether, ethylene, acetone, alcohol, benzene, butane, gasoline, hexane, lacquer solvent vapors, naphtha, natural gas or propane along with many other potentially hazardous materials.
WARNING: For FMS and EXP units where flammable materials are stored in the cooling chamber, the cooling chamber is considered a Class I Div1 or Class I Zone 1 hazardous location. Any monitoring devices placed in the cooling chamber must have an intrinsically safe rating from an appropriate certification body, such as UL, CSA, FM etc. (this includes battery or solar powered devices). Thermocouples for building monitoring systems must be wired through an electrical barrier designed to provide isolation against voltage and current spikes, which could cause a spark resulting in fire or explosion. It is the end user's responsibility to meet these requirements. The Fisher Scientific channel cannot assist with the selection of devices, recommend, approve or design any device or monitoring circuit.
If you are in the Southern California area and would like to save on shipping costs, please contact us before purchase to coordinate local pickup!
Shipping & Pickup Disclaimer
This item is listed for local pickup in the San Diego area. If you require shipping, please note that freight is billed separately and calculated on a case-by-case basis through our freight partners. We will provide you with a custom shipping quote as quickly as possible after purchase.
For the most accurate estimate, please contact us in advance with your delivery address and any special requirements (e.g., lift gate service, residential delivery). We work to make freight logistics smooth and cost-effective for you.