Charles River Endosafe PTS100 Portable Endotoxin Test System
The Charles River Laboratories Endosafe PTS100 is a portable endotoxin testing instrument designed for point-of-use bacterial endotoxin testing using compatible disposable Endosafe PTS cartridges.
The system combines a handheld spectrophotometer, temperature-controlled cartridge chamber, LCD, and numeric keypad in a compact unit. It was developed for rapid testing in pharmaceutical, biotechnology, medical device, research, and quality-control environments.
This is the original first-generation Endosafe PTS100, which has been discontinued by the manufacturer and replaced by the nexgen-PTS platform.
The photographed unit powers on, the display and keypad respond, and the instrument enters its system self-test sequence. A complete analytical test was not performed because compatible Endosafe PTS cartridges were not available.
Features
Portable bacterial endotoxin testing platform
Designed for compatible Endosafe PTS cartridges
Integrated LCD and numeric keypad
Temperature-controlled cartridge chamber
Point-of-use laboratory operation
Compact benchtop and portable configuration
Hinged protective cover
External 12 VDC power supply
Manufactured in the United States
Specifications
Manufacturer: Charles River Laboratories
Product: Endosafe Portable Test System
Model: PTS100 / Original Endosafe PTS
Product Code: RMPTS964-01
Serial Number: 8902
Test Type: Bacterial endotoxin testing
Detection Method: Cartridge-based spectrophotometric analysis
Compatible Consumables: Endosafe PTS test cartridges
Power Requirement: 12 VDC, 5 A
Display: Integrated LCD
Controls: Numeric keypad with menu and navigation controls
Calibration Date Shown: October 23, 2020
Calibration Due Date Shown: October 2021
Country of Manufacture: United States
Included
Charles River Laboratories Endosafe PTS100
AC/DC power adapter
Includes all accessories shown in the photographs.
No test cartridges, printer, manual, software, computer, or other accessories are included.
Condition
Pre-owned with cosmetic wear, discoloration, scratches, and marks consistent with previous use and storage. Please review the photographs for the exact cosmetic condition.
The unit powers on, the LCD and keypad respond, and the system enters its self-test sequence. Testing was limited to these functions. No cartridge-based endotoxin test was performed, and analytical accuracy was not verified.
The calibration shown on the instrument expired in October 2021. The unit is offered without current calibration or qualification. Professional inspection, calibration, and qualification are recommended before laboratory use, particularly in regulated applications.
This is a discontinued legacy PTS100 system. Buyers should verify cartridge compatibility, calibration availability, software requirements, and manufacturer support before purchasing.
Shipping
This item will be carefully packaged to ensure safe delivery.
Shipping costs are calculated automatically based on the buyer's location.
Local pickup is available in San Diego, California.
The Charles River Laboratories Endosafe PTS100 is a portable endotoxin testing instrument designed for point-of-use bacterial endotoxin testing using compatible disposable Endosafe PTS cartridges.
The system combines a handheld spectrophotometer, temperature-controlled cartridge chamber, LCD, and numeric keypad in a compact unit. It was developed for rapid testing in pharmaceutical, biotechnology, medical device, research, and quality-control environments.
This is the original first-generation Endosafe PTS100, which has been discontinued by the manufacturer and replaced by the nexgen-PTS platform.
The photographed unit powers on, the display and keypad respond, and the instrument enters its system self-test sequence. A complete analytical test was not performed because compatible Endosafe PTS cartridges were not available.
Features
Portable bacterial endotoxin testing platform
Designed for compatible Endosafe PTS cartridges
Integrated LCD and numeric keypad
Temperature-controlled cartridge chamber
Point-of-use laboratory operation
Compact benchtop and portable configuration
Hinged protective cover
External 12 VDC power supply
Manufactured in the United States
Specifications
Manufacturer: Charles River Laboratories
Product: Endosafe Portable Test System
Model: PTS100 / Original Endosafe PTS
Product Code: RMPTS964-01
Serial Number: 8902
Test Type: Bacterial endotoxin testing
Detection Method: Cartridge-based spectrophotometric analysis
Compatible Consumables: Endosafe PTS test cartridges
Power Requirement: 12 VDC, 5 A
Display: Integrated LCD
Controls: Numeric keypad with menu and navigation controls
Calibration Date Shown: October 23, 2020
Calibration Due Date Shown: October 2021
Country of Manufacture: United States
Included
Charles River Laboratories Endosafe PTS100
AC/DC power adapter
Includes all accessories shown in the photographs.
No test cartridges, printer, manual, software, computer, or other accessories are included.
Condition
Pre-owned with cosmetic wear, discoloration, scratches, and marks consistent with previous use and storage. Please review the photographs for the exact cosmetic condition.
The unit powers on, the LCD and keypad respond, and the system enters its self-test sequence. Testing was limited to these functions. No cartridge-based endotoxin test was performed, and analytical accuracy was not verified.
The calibration shown on the instrument expired in October 2021. The unit is offered without current calibration or qualification. Professional inspection, calibration, and qualification are recommended before laboratory use, particularly in regulated applications.
This is a discontinued legacy PTS100 system. Buyers should verify cartridge compatibility, calibration availability, software requirements, and manufacturer support before purchasing.