Bio-Rad Criterion Blotter 170-4070 Electrophoretic Transfer Cell
The Bio-Rad Criterion Blotter 170-4070 is a wet-tank electrophoretic transfer system designed for Western blotting, protein transfer, and nucleic acid transfer applications.
This is the plate-electrode version, using a platinum-coated titanium anode and stainless steel cathode. The system accommodates up to two Criterion gels or four Mini-PROTEAN gels and uses approximately 1.3 L of transfer buffer.
This pre-owned unit is in good overall cosmetic condition with normal signs of previous laboratory use. The tank, safety lid, integrated power leads, plate electrodes, two gel holder cassettes, and sealed ice cooling block are included as shown.
An external compatible power supply is required and is not included.
Includes all accessories shown in the photographs.
Features
Plate-electrode wet transfer system
Designed for Western blotting and protein transfer
Suitable for nucleic acid transfer applications
Capacity for up to 2 Criterion gels
Capacity for up to 4 Mini-PROTEAN gels
Maximum gel size of 15 × 9.4 cm
1.3 L buffer capacity
Platinum-coated titanium anode
Stainless steel cathode
Safety lid with integrated red and black power leads
Sealed ice cooling block
Durable laboratory-grade construction
Specifications
Manufacturer: Bio-Rad Laboratories
Product: Criterion Blotter
Catalog Number / MPN: 170-4070
Electrode Type: Plate Electrodes
Anode: Platinum-Coated Titanium
Cathode: Stainless Steel
Maximum Gel Size: 15 × 9.4 cm
Gel Capacity: 2 Criterion Gels or 4 Mini-PROTEAN Gels
Buffer Capacity: 1.3 L
Electrode Distance: 4.3 cm
Maximum Voltage: 300 VDC
Maximum Power: 200 W
Dimensions: Approximately 8.6" × 4.6" × 5.9"
Weight: Approximately 2.9 lb
Application: Electrophoretic Protein / Western Blot Transfer
Product Status: Discontinued
Included
Bio-Rad Criterion Blotter tank
Safety lid with integrated power leads
Plate electrode assembly
2 gel holder cassettes
1 sealed ice cooling block
Includes all accessories shown in the photographs.
Not Included: External power supply, gel/blot assembly tray, roller, fiber pads, and filter paper.
Condition
Pre-owned and in good overall cosmetic condition with normal signs of previous laboratory use.
The tank, lid, power leads, electrode components, gel holder cassettes, and cooling block appear intact.
The unit has not been functionally tested with a compatible external power supply.
Please review all photographs for the exact condition, configuration, and included components.
Shipping
This item will be carefully packaged to ensure safe delivery.
Shipping costs are calculated automatically based on the buyer's location.
Local pickup is available in San Diego, California.
The Bio-Rad Criterion Blotter 170-4070 is a wet-tank electrophoretic transfer system designed for Western blotting, protein transfer, and nucleic acid transfer applications.
This is the plate-electrode version, using a platinum-coated titanium anode and stainless steel cathode. The system accommodates up to two Criterion gels or four Mini-PROTEAN gels and uses approximately 1.3 L of transfer buffer.
This pre-owned unit is in good overall cosmetic condition with normal signs of previous laboratory use. The tank, safety lid, integrated power leads, plate electrodes, two gel holder cassettes, and sealed ice cooling block are included as shown.
An external compatible power supply is required and is not included.
Includes all accessories shown in the photographs.
Features
Plate-electrode wet transfer system
Designed for Western blotting and protein transfer
Suitable for nucleic acid transfer applications
Capacity for up to 2 Criterion gels
Capacity for up to 4 Mini-PROTEAN gels
Maximum gel size of 15 × 9.4 cm
1.3 L buffer capacity
Platinum-coated titanium anode
Stainless steel cathode
Safety lid with integrated red and black power leads
Sealed ice cooling block
Durable laboratory-grade construction
Specifications
Manufacturer: Bio-Rad Laboratories
Product: Criterion Blotter
Catalog Number / MPN: 170-4070
Electrode Type: Plate Electrodes
Anode: Platinum-Coated Titanium
Cathode: Stainless Steel
Maximum Gel Size: 15 × 9.4 cm
Gel Capacity: 2 Criterion Gels or 4 Mini-PROTEAN Gels
Buffer Capacity: 1.3 L
Electrode Distance: 4.3 cm
Maximum Voltage: 300 VDC
Maximum Power: 200 W
Dimensions: Approximately 8.6" × 4.6" × 5.9"
Weight: Approximately 2.9 lb
Application: Electrophoretic Protein / Western Blot Transfer
Product Status: Discontinued
Included
Bio-Rad Criterion Blotter tank
Safety lid with integrated power leads
Plate electrode assembly
2 gel holder cassettes
1 sealed ice cooling block
Includes all accessories shown in the photographs.
Not Included: External power supply, gel/blot assembly tray, roller, fiber pads, and filter paper.
Condition
Pre-owned and in good overall cosmetic condition with normal signs of previous laboratory use.
The tank, lid, power leads, electrode components, gel holder cassettes, and cooling block appear intact.
The unit has not been functionally tested with a compatible external power supply.
Please review all photographs for the exact condition, configuration, and included components.
Shipping
This item will be carefully packaged to ensure safe delivery.
Shipping costs are calculated automatically based on the buyer's location.
Local pickup is available in San Diego, California.